logo
Qingdao Xinmeiteng Sponge Manufacture Co.
Products
Products
Home > Products > Foam Recycling Machine > 1500 Mesh Stainless Filter Foam Dust Collector with Cyclone Separator and Fireproof Level A

1500 Mesh Stainless Filter Foam Dust Collector with Cyclone Separator and Fireproof Level A

Product Details

Place of Origin: Qingdao

Brand Name: Xinmeiteng

Certification: CE

Model Number: C516

Payment & Shipping Terms

Minimum Order Quantity: 1 Set

Price: Inquiry

Packaging Details: TO BE DETERMINED

Delivery Time: 45 working days after downpayment

Payment Terms: L/C,T/T

Supply Ability: 3 sets per season

Get Best Price
Highlight:

1500 Mesh Stainless Filter

,

Cyclone Separator Dust Collector

,

Two Stage Foam Dust Filtration

Motor Power:
1.5 KW / 2.2 KW
Voltage:
220 V / 380 V
Weight:
200 Kg
Overall Dimension:
1200*650*1750 Mm
Stainless Steel Filter:
2 X 1500 Mesh
Cyclone Separator:
One
Motor Power:
1.5 KW / 2.2 KW
Voltage:
220 V / 380 V
Weight:
200 Kg
Overall Dimension:
1200*650*1750 Mm
Stainless Steel Filter:
2 X 1500 Mesh
Cyclone Separator:
One
1500 Mesh Stainless Filter Foam Dust Collector with Cyclone Separator and Fireproof Level A
C516 Foam Dust Collector with Two 1500 Mesh Stainless Filters

The C516 is a two-stage foam dust collector. A cyclone separator removes coarse dust first, then air passes through two 1500 mesh stainless steel filter elements. Motor power is 1.5 kW or 2.2 kW, voltage is 220 V or 380 V, weight is 200 kg and the overall dimension is 1200*650*1750 mm.

The dust that matters in a foam workshop is the fine fraction, the part that stays in the air and reaches the operator. A single filter handles it for a while, then loads up and suction falls. The C516 splits the job: the cyclone takes the coarse dust out of the air stream, and the two stainless filters handle what is left.

C516 foam dust collector cabinet and fan unit
C516 foam dust collector cabinet and fan unit.
The Machine at a Glance

Cyclone pre-separation

Coarse foam dust drops out before it reaches the filter elements.

2 x 1500 mesh

Two stainless steel elements catch the fine dust that stays airborne.

Washable stainless

The elements are cleaned and reused instead of replaced every cycle.

Open airflow path

Less dust on the filter means suction holds for longer between cleans.

  • Model: C516
  • Fire-proof level: Level A (non-combustible)
  • Motor power: 1.5 kW / 2.2 kW
  • Voltage: 220 V / 380 V
  • Filter: 2 x 1500 mesh stainless
  • Weight: 200 kg
C516 dust collector stainless steel filter element
C516 dust collector stainless steel filter element.
C516 fireproof dust collection system with stainless steel filter
C516 fireproof dust collection system with stainless steel filter.
Following the Air Through the C516
  1. Hood. Dust is captured at the cutting or trimming point.
  2. Duct. The fan carries dust-laden air into the unit.
  3. Cyclone. Coarse particles drop out of the air stream.
  4. First filter. Air passes through the first 1500 mesh element.
  5. Second filter. The second element catches the remaining fine dust.
  6. Clean air out. Filtered air returns to the workshop.

Check the filter from the dirty side, not the clean side. Dust on the clean side of an element means it was seated wrong or the seal is worn, not that the mesh has failed.

What 1500 Mesh Does That a Coarse Filter Cannot

A coarse filter catches the chips and lets the fine dust through. Fine foam dust is the fraction that stays suspended, reaches the operator and settles on every surface in the workshop. A 1500 mesh stainless element is fine enough to take that fraction out of the air stream before it is discharged.

Two elements in series are not redundancy. The first element takes the bulk of the load, the second polishes the air. That arrangement keeps the final discharge clean for longer and gives the operator a visible sign, a loaded first element, that it is time to clean.

Stainless elements also change the running cost. They are washed and reused, so the consumable is cleaning time rather than replacement media. In a workshop running daily, that difference is more significant than the purchase price of the filter.

  • Fine dust capture: 1500 mesh removes the airborne fraction.
  • Two-stage loading: the first element takes the bulk, the second polishes.
  • Reusable elements: wash and refit instead of replacing media.
Clean the first element more often than the second. It carries most of the dust, and keeping it clear is what protects the final discharge quality.
C516 dust collector stainless steel filter element
C516 stainless steel filter element in the filter chamber.
Technical Parameters
Parameter Value
Model C516
Machine type Fireproof dust collection system
Fire-proof level Level A (non-combustible)
Motor power 1.5 kW / 2.2 kW
Voltage 220 V / 380 V
Cyclone separator One
Stainless steel filter 2 x 1500 mesh
Weight 200 kg
Overall dimension 1200*650*1750 mm
Certification CE
Core Advantages
  • Two-stage filtration: cyclone first, stainless mesh second.
  • 1500 mesh elements: fine foam dust is captured before the air is discharged.
  • Washable filters: clean and reuse the elements instead of buying disposable media.
  • Stable suction: coarse dust never reaches the filter, so it loads more slowly.
  • Metal filter chamber: the elements sit in a non-combustible housing.
  • Compact unit: 1200*650*1750 mm, sits beside the cutting area.
  • CE certified: export-ready electrics and guarding.
Primary Applications
  • Foam cutting: fine dust captured at the blade hood.
  • Foam shredding: dust from granulators and shredder outlets.
  • CNC foam routing: extraction at the cutting head.
  • Mattress trimming: fine trim dust from edging lines.
  • Rebond mixing: dust control around scrap handling.
  • Workshop extraction: hose kit for general clean-up.
C516 dust collection system cyclone separator
C516 dust collection system cyclone separator.
C516 fireproof dust collector installed in a foam workshop
C516 fireproof dust collector installed in a foam workshop.
C516 dust extraction unit with duct connection
C516 dust extraction unit with duct connection.
Dust Collector Faults and Their Causes
Symptom Likely cause Action
Weak suction at the hood Filter clogged or duct joint leaking Clean the filters and check every duct joint
Dust escapes from the cabinet Door seal worn or filter seated wrong Replace the seal and reseat the filter
Motor overheats Blocked duct or too many hoods on one unit Clear the blockage and check motor current
Filter tears early Sharp debris or wrong mesh fitted Fit the correct 1500 mesh filter and check the inlet
Unit vibrates Fan imbalance or loose mounting Balance the fan and tighten the mounts
Dust settles in the duct Air velocity too low for the run Shorten the duct run and check fan speed

Dust collector faults usually appear as falling suction before they appear as a motor fault. Check the filter, the duct joints and the number of open hoods first, because those three account for most weak-suction complaints.

Operation and Filter Handling

Isolate the power before opening the filter chamber. The fan can still be moving air, and the filter chamber holds the dust that was just removed from the air stream.

Reseat the elements squarely when refitting. A filter that sits at an angle lets dust bypass the mesh and shows up later as dust on the clean side of the chamber.

  • Check suction at the hood at the start of each shift.
  • Clean the first filter element on a shorter interval than the second.
  • Isolate power before opening the filter chamber.
  • Reseat each element squarely and close the door seal properly.
  • Record cleaning dates so the interval can be adjusted to the dust load.
C516 dust extraction unit with duct connection
C516 dust extraction unit with duct connection.
Filter Care and Daily Maintenance

The stainless elements are the core wear part. Wash them on the interval that matches the dust load, inspect the mesh for damage and replace any element that is torn rather than patched.

The cyclone needs less attention but should be checked for build-up. Coarse dust that bridges in the cyclone cone stops separating properly and sends the load to the filters.

  • Wash the stainless filter elements on a fixed interval.
  • Inspect the mesh for tears and replace damaged elements.
  • Check the cyclone cone for bridging or build-up.
  • Check the door seal and duct joints weekly.
  • Check fan mounting and motor current monthly.
C516 fireproof dust collection system with stainless steel filter
C516 dust collection system with stainless filter.
Packaging and Delivery

The unit ships in an export crate with the cabinet, fan and both filter elements braced for transport. The crate is sized to the 1200*650*1750 mm machine envelope.

The shipment includes the filter specification, duct connection sizes and a commissioning checklist, with remote support during installation.

C516 dust collector filter access door
C516 dust collector filter access door.
Frequently Asked Questions
Q1: How many filter elements does the C516 use?

A: Two 1500 mesh stainless steel elements, after a cyclone separator.

Q2: Are the filters reusable?

A: Yes. The stainless elements are washed and refitted, not replaced every cycle.

Q3: What dust does the C516 capture?

A: Coarse dust in the cyclone and the fine airborne fraction in the two mesh elements.

Q4: What are the motor and voltage options?

A: 1.5 kW or 2.2 kW, on 220 V or 380 V supply.

Send Your Dust Control Requirement

Tell us the dust source, number of machines on the duct run, duct length and the voltage available on site. We will confirm the motor size, filter configuration and hood layout, then quote it with the delivery schedule. Spare filters and ducting parts are available with every order.